Democracy Spraffa

Shop at The Inn - Layout Plan

Argyll and Bute Council · 24 September 2024
Back to Argyll and Bute Licensing Board — 24 September 2024 and its agenda

Text extracted from the council's PDF. Layout and reading order may differ from the original.

Original council PDF · Download plain text

Page 1

Staff / tea prep Staff w.c.
up
up
FAP CPA
1
up
2
1in 20 Ramp up
E
E.E
HD
sink
E
The Birches
Glenevan
Community Centre
Smithy
Pennyghael
Cave
Pennyghael Bridge
Shingle
Leidle River
Inn at Port Na Gael
to CRAIGNURE
A849
to FIONNPHORT
Beaton + McMurchy
tel - 01866 822350  fax - 01866 822320
tigh na glaic, taynuilt, argyll. pa35 1jw
Drawing No. Revision
e-mail     mail@bmarchitects.co.uk
architects
Drawing
Drawn by
CAD Filename:
Drawing Scale:
Date:
Project
Client
CMD
2 4 1 4         L D  0 1      A
A2 @ 1:100
MAY 2024
LICENSING DRAWING
PORT NAN GAEL SHOP,
PENNYGHAEL,
ISLE OF MULL,
PA70 6HB
MULL HOTELS LTD.
web       www.bmarchitects.co.uk
1 2 3 4 5 100
10 2 3 4 5 10 20 30
1 2 3 4 5 10 0
10 2 3 4 5 10 20 30 feet
SCALE
metres
FLOOR PLAN
L O C A T I O N P L A N 1 : 2 5 0 0
Extent of property
Extent of Customer Area
n
n
F L O O R P L A N 1 : 1 0 0
Fire Warning System to comply with British Standard 5839: Part 1 :
2019
Every part of an escape route to have artificial lighting supplied
by a protected circuit that provides a level of illumination not less
than that recommended in BS 5266 Part 1 2005 (Maintained -2
hour duration) and BS EN 1838: 1999 (OR BS 5266-7: 1999)
Firefighting Equipment to comply with British Standard EN3, British
Standard 7863 : 1996, British Standard 5306-8:200
Signs and Notices to comply with the Health and Safety (Safety
Signs and Signals) Regulations 1996 and/or British Standard 5499:
Part 1 : 1990.
Note: Drawing prepared for application for Licensing Board only.
exit Emergency exit light with 2 hour battery back up
E Emergency light with 2 hour battery back up
E.E External Emergency light with 2 hour battery back up
FAP
Fire alarm panel
Manual FA Call pointCPA
Shop
Area used to display alcohol
(total frontage approx. 18.5m²)
2400 x 2200 mm
approx. Shelving for
alcohol display
(spirts)
STAFF ONLY ACCESSSTAFF ONLY ACCESS
8.3m
or thereby
13.6m or thereby
Counter
EXIT
SD
E
SD
900mm
fire escape
Smoke detector with sounder
Heat detector with sounderHD
SD
FIRE ESCAPE ROUTE
6000 x 2200 mm approx. shelving / fridges