Taynuilt Hotel - Layout Plan
Argyll and Bute Council · 22 April 2025
Back to Argyll and Bute Licensing Board — 22 April 2025 and its agenda
Text extracted from the council's PDF. Layout and reading order may differ from the original.
Page 1
n Beaton + McMurchy tel - 01866 822350 fax - 01866 822320 tigh na glaic, taynuilt, argyll. pa35 1jw Drawing No. Revision e-mail mail@bmarchitects.co.uk architects Drawing Drawn by CAD Filename: Drawing Scale: Date: Project Client CMD 2 2 1 4 L D 0 1 C A1 @ 1:100 JULY 2024 LICENSING DRAWING THE TAYNUILT INN, TAYNUILT, ARGYLL, PA35 1HF TAYNUILT (INN) LTD web www.bmarchitects.co.uk 1 2 3 4 5 100 10 2 3 4 5 10 20 30 1 2 3 4 5 10 0 10 2 3 4 5 10 20 30 feet SCALE metres GROUND FLOOR PLAN / SITEPLAN Note: Drawing prepared for application for Licensing Board only. GROUND FLOOR PLAN 1:100 ES Female w.c. dry store Cellar dis / staff w.c. Terrace up Corridor Porch Male w.c. Kitchen up up up Stairwell Walk in Chill Walk in Freeze up Bar Corridor 3 2 1 4 5 6 7 Restaurant up up FAP E E E E E E EXIT EXIT EXIT EXIT EXIT EXIT ES EXIT EXIT CPA CMD HD HD HD HD SD SD SD SD SD SD SD ES ES E.E E.E E.E E.E E.E E.E E.E E.E E.E CPA CPA E.E E.E E.E kegs floor drain wine / beer / spirit store SD SD SD SD T A Y N U I L T Ashlea 6 1 710 16 33 17 Cruidhean Annait 3 12 Truim WarMeml B 845 A 85 2 Church 1 TaynuiltHotel Cearnduil Dunetive Fasnakyle The Knowe Gar-na-CoullPO CottageThe PoliceStation Muasdale Tel Ex Duncruachan Achabuie Doonside To Oban To Dalmally LOCATION PLAN 1:2500 FIRE SERVICES / DETECTION KEY Fire Warning System to comply with British Standard 5839: Part 1 : 2019 Every part of an escape route to have artificial lighting supplied by a protected circuit that provides a level of illumination not less than that recommended in BS 5266 Part 1 2005 (Maintained -2 hour duration) and BS EN 1838: 1999 (OR BS 5266-7: 1999) Firefighting Equipment to comply with British Standard EN3, British Standard 7863 : 1996, British Standard 5306-8:200 Signs and Notices to comply with the Health and Safety (Safety Signs and Signals) Regulations 1996 and/or British Standard 5499: Part 1 : 1990. The applicant must ensure that the upholstered furniture satisfies the Cigaretter and Match Ignitability Test specified in Britsh Standard 5852: 1990 (1998). (NOTE - for existing furnishings only) A Certificate of Comliance to the aforementioned British Standards should be issued by a competent person and forwarded to the Fire Authority prior to, or on the date of the final inspection of the premises exit Emergency exit light with 2 hour battery back up E Emergency light non maintained E.E External Emergency light with 2 hour battery back up FAP Fire alarm panel Water portable fire extinguisher and size/capacity Foam portable fire extinguisher and size/capacity WE FE Wet chemical portable fire extinguisher and size/capacity CHE Fire blanket FB Manual call point Extent of property Extent of Customer Area Total Customer Area (m2) Restaurant - 46m2 Bar - 27m2 External Seating Area -87m2 Public Occupancy of Premises (based on occupancy load factor of 0.5 for Bar) 27m2 = 54 persons (based on occupancy load factor of 1.0 for Restaurant) 46m2 = 46 persons (based on occupancy load factor of 1.0 for external seating) 87m2 = 87 persons TOTAL INTERNAL OCCUPANCY - 100 PERSONS STAFF ONLY STAFF ONLY OPTICAL SMOKE DETECTOR WITH C/W SOUNDER BASE OSD/ SB OPTICAL SMOKE DETECTORSD OPTICAL HEAT DETECTORHD HEAT DETECTOR WITH C/W SOUNDER BASE HD/ SB MULTI SENSOR WITH C/W SOUNDER BASE OPTICAL SMOKE DETECTOR WITH C/W SOUNDER BASE AND LED STROBE LIGHT HEAT DETECTOR WITH C/W SOUNDER BASE AND LED STROBE LIGHT MULTI SENSOR WITH C/W SOUNDER BASE AND LED STROBE LIGHT MS/ SB OSD/ SB/ SL HD/ SB/ SL MS/ SB/ SL OPTICAL CARBON MONOXIDE DETECTORSD 950mm fire escape 1250mm fire escape 950mm fire escape 950mm fire escape External seating area External seating area