60 Mile Inn - Layout Plan
Argyll and Bute Council · 22 April 2025
Back to Argyll and Bute Licensing Board — 22 April 2025 and its agenda
Text extracted from the council's PDF. Layout and reading order may differ from the original.
Page 1
BT BT BT Existing stone wall separating partition 300mm thick 826 826 826 30min FD 926 30min FD 926 926 30min FD 826 30min FD 726 826 726 826 Existing partition altered for new bar area and staff access Existing window removed and new door fitted Existing window removed and new door fitted Escape window 800 clear width 800 clear width 775 clear width 650 clear width 775 clear width 775 clear width 775 clear width 775 clear width 650 clear width Ramp gradient 1:15 Dropped kerb to be provided from accessible parking area to path towards accessible entrance See Building regullation Clause 4.1.7 for specifiction for accessible entrance to cafe. 100mm upstand Escape window Escape window Escape window to extend to under side of sarking Sink Cooker Accessible toilet fixtures to fully comply with building standards regulation 3.12.7 including emergency pull cord etc. Concrete ramp gradient 1:15 BT BT BT HD TV TV RAD RAD RAD PIR PIR PIR PIR PIR PIR PIR PIR PIR PIR PIR PIR PIR PIR PIR PIR PIR PIR x2 x2 TV RAD RAD RAD RAD RAD RAD RAD HD SD SD SD A A B B Living Bedroom Bedroom Cafe Bar/prep Bedroom Cafe Acc.WC WC Store SD SD SD CATEGORY L2 FIRE ALARM SYSTEM THROUGHOUT. 60L/sec 60L/sec 60L/sec 60L/sec 60L/sec 60L/sec DUAL FLUSH AND WATER EFFICIENT FITTINGS TO BE USED IN ALL BATHROOM APPLIANCES. ELECTRICAL WORKS IN ACCORDANCE WITH BS 7671: 2018 AS AMENDED. Sink Cooker Kitchen Area Timber ramp gradient 1:15 DECKING DECKING DOUBLE SWITCHED SOCKET BT POINT 1 WAY SWITCH TV POINT SHAVER SOCKET EXTERNAL LIGHT - MS INDICATES MOTION SENSOR FOR AUTOMATIC ILLUMINATION SMOKE DETECTOR EXTRACTOR FAN WALL LIGHT CONSUMER UNIT / METER PENDANT LIGHT FITTING HEAT DETECTOR PULL CHORD COOKER CONTROL UNIT CARBON DIOXIDE DETECTOR Note The contractor will be held to have checked all dimensions before commencing with any works and, in the event of discrepancies, is to refer them directly to this office for clarification prior to commencement of work. Written dimensions are to be taken in all cases. Drawings should not be scaled for dimensions. In case of doubt refer to this office. This drawing is copyright and all rights are reserved. No unauthorised copying of this drawing is permitted. SINGLE SWITCHED SOCKET (FS = Fused spur) ELECTRICAL LEGEND CARBON MONOXIDE DETECTOR Notes: Mains operated smoke detectors to BS 5446 & BS 5839. Detectors interconnected and permanently wired to a protected circuit with minimum 72 hours battery back up. All glass and glazing to BS 6262. All glazing at or below 800mm from floor level to be toughened / laminated glass. Internal door glazing to have single toughened glazing. Emergency escape windows provided to all apartments at first floor level and all inner rooms. Windows to have an unobstructed openable area that is at least 0.33m2 and at least 450mm high and 450mm wide. Bottom of the openable area should be between 900-1100mm above finished floor level. PELMET LIGHTING CARBON DIOXIDE DETECTOR = CO2 THE OAKS, PERTH PLACE, FORT WILLIAM, PH33 6UL 07429 489537 ADMIN@JCARCHITECTURE.CO.UK scale detail project drawnjob no. Proposed alterations & extension The Old Schoolhouse, Bridge of Orchy 1:50 - A1 client date drg no. May 2024 302C24/011 JJC Mr. Charlie Duthie Working Drawing 2 - Ground floor new works & dimensions / electrical, internal drainage & heating New works & dimensions Electrical, internal drainage & heating layout External to internal: 22mm timber lining 45x45mm batten 15x45mm batten 9mm plywood sheathing 140mm timber kit with 140mm Celotex inset 50mm Celotex across face of studs Vapour control layer 25mm strap 12.5mm plasterboard 95mm stud partition with 90mm Rockwool Flexi inset between studs 12.5mm Gyproc Ten Plasterboard to both sides External to internal: 100mm block with render to match existing 50mm Cavity 95mm timber kit with 90mm Celotex inset 50mm Celotex across face of studs Vapour control layer 25mm strap 12.5mm plasterboard External to internal: Existing stone wall 30mm cavity 140mm timber kit with 140mm Celotex inset 50mm Celotex across face of studs 25mm service strap 12.5mm plasterboard External to internal: Existing stone wall Existing lath & plaster 140mm timber kit with 140mm Celotex inset 25mm service strap 12.5mm plasterboard External to internal: Existing double block wall 140mm timber kit with 140mm Celotex inset 50mm Celotex across face of studs 25mm service strap 12.5mm plasterboard External to internal: 22mm timber cladding 45x45mm batten 15 x 45mm batten 96mm timber kit with 140mm Celotex inset 9mm plywood sheathing Rev. A. Drawing amended as per building regulations - JJ 27.11.24 Rev. B. Drawing amended as per building regulations - JJ 17.01.25 Rev. C. Drawing amended for building control - JJ 07.02.25