60 Mile Inn - Layout Plan

Argyll and Bute Council · 22 April 2025
Back to Argyll and Bute Licensing Board — 22 April 2025 and its agenda

Text extracted from the council's PDF. Layout and reading order may differ from the original.

Original council PDF · Download plain text

Page 1

BT
BT
BT
Existing stone wall separating partition 300mm thick
826
826
826
30min FD
926
30min
FD
926
926
30min FD
826
30min FD
726
826
726
826
Existing partition altered for
new bar area and staff access
Existing window removed and
new door fitted
Existing window
removed and new
door fitted
Escape window
800 clear
width
800 clear
width
775 clear
width
650 clear
width
775 clear
width
775 clear
width
775 clear
width
775 clear
width
650 clear
width
Ramp gradient 1:15
Dropped kerb to be provided
from accessible parking area
to path towards accessible
entrance
See Building regullation
Clause 4.1.7 for specifiction
for accessible entrance to
cafe.
100mm upstand
Escape window
Escape window
Escape window
to extend to under side of sarking
Sink
Cooker
Accessible toilet
fixtures to fully
comply with building
standards regulation
3.12.7 including
emergency pull cord
etc.
Concrete ramp
gradient 1:15
BT
BT
BT
HD
TV
TV
RAD
RAD
RAD
PIR
PIR
PIR
PIR
PIR
PIR
PIR PIR
PIR
PIR
PIR
PIR
PIR
PIR
PIR
PIR
PIR
PIR x2
x2
TV
RAD
RAD
RAD
RAD
RAD
RAD
RAD
HD
SD
SD
SD
A A
B B
Living
Bedroom
Bedroom
Cafe
Bar/prep
Bedroom
Cafe
Acc.WC
WC
Store
SD
SD
SD
CATEGORY L2 FIRE ALARM SYSTEM THROUGHOUT.
60L/sec
60L/sec
60L/sec
60L/sec
60L/sec
60L/sec
DUAL FLUSH AND WATER  EFFICIENT FITTINGS TO
BE USED IN ALL BATHROOM APPLIANCES.
ELECTRICAL WORKS IN ACCORDANCE WITH BS 7671: 2018 AS AMENDED.
Sink
Cooker
Kitchen
Area
Timber ramp
gradient 1:15
DECKING
DECKING
DOUBLE SWITCHED SOCKET
BT POINT                 
1 WAY SWITCH                    
TV POINT                        
SHAVER SOCKET
EXTERNAL LIGHT - MS INDICATES MOTION
SENSOR FOR AUTOMATIC ILLUMINATION
SMOKE DETECTOR
EXTRACTOR FAN
WALL LIGHT
CONSUMER UNIT / METER
PENDANT LIGHT FITTING    
HEAT DETECTOR
PULL CHORD            
COOKER CONTROL UNIT
CARBON DIOXIDE DETECTOR
Note
The contractor will be held to have checked all dimensions before
commencing with any works and, in the event of discrepancies, is to
refer them directly to this office for clarification prior to
commencement of work.
Written dimensions are to be taken in all cases. Drawings should not
be scaled for dimensions. In case of doubt refer to this office.
This drawing is copyright and all rights are reserved. No unauthorised
copying of this drawing is permitted.
SINGLE SWITCHED SOCKET (FS = Fused spur)
ELECTRICAL LEGEND
CARBON MONOXIDE DETECTOR
Notes:
Mains operated smoke detectors to BS 5446 & BS 5839. Detectors
interconnected and permanently wired to a protected circuit with
minimum 72 hours battery back up.
All glass and glazing to BS 6262. All glazing at or below 800mm from
floor level to be toughened / laminated glass. Internal door glazing to
have single toughened glazing.
Emergency escape windows provided to all apartments at first floor
level and all inner rooms. Windows to have an unobstructed openable
area that is at least 0.33m2 and at least 450mm high and 450mm
wide. Bottom of the openable area should be between 900-1100mm
above finished floor level.
PELMET LIGHTING
CARBON DIOXIDE DETECTOR = CO2
THE OAKS, PERTH PLACE, FORT WILLIAM, PH33 6UL
07429 489537 ADMIN@JCARCHITECTURE.CO.UK
scale
detail
project
drawnjob no.
Proposed alterations & extension The Old
Schoolhouse, Bridge of Orchy
1:50 - A1
client
date
drg no.
May 2024
302C24/011 JJC
Mr. Charlie Duthie
Working Drawing 2 - Ground floor new
works & dimensions / electrical, internal
drainage & heating
New works & dimensions Electrical, internal drainage & heating layout
External to internal:
22mm timber lining
45x45mm batten
15x45mm batten
9mm plywood sheathing
140mm timber kit with 140mm Celotex inset
50mm Celotex across face of studs
Vapour control layer
25mm strap
12.5mm plasterboard
95mm stud partition with 90mm Rockwool
Flexi inset between studs
12.5mm Gyproc Ten Plasterboard to both
sides
External to internal:
100mm block with render to match existing
50mm Cavity
95mm timber kit with 90mm Celotex inset
50mm Celotex across face of studs
Vapour control layer
25mm strap
12.5mm plasterboard
External to internal:
Existing stone wall
30mm cavity
140mm timber kit with 140mm Celotex inset
50mm Celotex across face of studs
25mm service strap
12.5mm plasterboard
External to internal:
Existing stone wall
Existing lath & plaster
140mm timber kit with 140mm Celotex inset
25mm service strap
12.5mm plasterboard
External to internal:
Existing double block wall
140mm timber kit with 140mm Celotex inset
50mm Celotex across face of studs
25mm service strap
12.5mm plasterboard
External to internal:
22mm timber cladding
45x45mm batten
15 x 45mm batten
96mm timber kit with 140mm Celotex inset
9mm plywood sheathing
Rev. A.
Drawing amended as per building regulations - JJ
27.11.24
Rev. B.
Drawing amended as per building regulations - JJ
17.01.25
Rev. C.
Drawing amended for building control - JJ 07.02.25