Item 4.04 - The Clipper - Layout Plan
West Dunbartonshire Council · 27 October 2026
Back to Licensing Board — 27 October 2026 and its agenda
Text extracted from the council's PDF. Layout and reading order may differ from the original.
Page 1
FC=960 CH=1090 STORE GENTS CELLAR CELLAR LOBBY ELECTRICS CONSERVATORY 17 to 21 TCB 4.3m 1216 1018 8 6 4 2 BEER GARDEN FC=1200 CH=2982 FC=1200 CH=2982 FC=1200 CH=2982 FC=1200 CH=2982 FC=1200 CH=2982 BAR SERVERY GLASS WASH DARTS DOUBLE SINK DRAINER GLASSWASH ICE MACHINE (CUBED) 704 (w), 1510 (h), 665n (d) ICE MACHINE (CRUSHED) 940 (w), 800 (h), 600 (d) GLASSWASH CLEANERS CUPBOARD NEW TV NEW TV NEW TV NEW TV NEW TV NEW TV NEW TV NEW TV ACCESS HATCH BEER GARDEN DELIVERIES ACCESS R=170 R=170 R=200 DELIVERIES ACCESS 3 4 5 6 7 8 9 10 11 1221 13 14 15 16 17 18 LandingLanding 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 NEW EMERGENCY ESCAPE STAIR CASE UP TO MANAGERS FLAT 245SQM TRADE AREA SP HD FIRE ESCAPE STAIR ACCESSIBLE WC FIRE LOBBY LADIES HD HD HD S EMERGENCY EXIT H ELECTRICS KEY (PROPOSED) New emergency light fitting (to be in accordance with BS5266 Part 1 and BSEN 1838 New external emergency light fitting, connected into existing system (to be in accordance with BS5266 Part 1 1999 and BSEN 1838. Smoke detector, linked to fire alarm system, sufficient fittings to be provided to comply with BS5839-1:2013 and designed in accordance with approved document L2. New fire alarm sounder connected into existing system New illuminated emergency exit sign connected into existing system (to be in accordance with BS5499. Heat detector, linked to fire alarm system, sufficient fittings to be provided to comply with BS5839-1 : 2013 and designed in accordance with approved document L2. Break Glass point S S S S S S S S S S H EMERGENCY EXIT EMERGENCY EXIT EMERGENCY EXIT EMERGENCY EXIT EMERGENCY EXIT HIGHSTREET LICENSED AREA LEGEND 'ACTIVITIES WILL OCCUR THROUGHOUT THE PREMISES IN ACCORDANCE WITH THE APPROVED OPERATING PLAN' Note: All fire strategy shown as indicitive positions for licensing purposes only. AWP GAMES MACHINE Existing EDA - 248sqm Proposed EDA - 248sqm Building perimeter area - 467sqm AWP AWP AWP AWP S EMERGENCYEXIT EMERGENCY EXIT B B B B B B Suite I, Sheffield Business Park Ltd Sheffield Business Centre, Europa Link Sheffield, S9 IXZ Tel: 07535 318060 Email: office@conceptdesign.uk.net Website: www.conceptdesign.org.uk Architecture - Interior Design - Project Management Copyright. This drawing and design and all the information contained therein is the sole copyright of Concept IDL and reproduction in any form is forbidden unless permission isobtained in writing. CONTRACTORS PLEASE NOTE 1) Warning, no dimensions to be scaled from this drawing.All contractors to visit the site and be responsible for taking and checking all dimensions relative to this work. The designer must be advised of any discrepancies in writing. 2) This drawing must be read in conjunction with the specification / bill of quantities and related drawings. Any structural work must be carried out to the exact specification and requirements of theclients's appointed structural engineer, and any amendments must have his express prior written authority. 3) All structural work must be inspected at all relevant stages by the structural engineer and the Local Authority's Building Surveyor and comply with their requirements. Any costs and claims for damages, loss of trade, etc. incurred by failing so to do are the sole liability of the contractor. 4) Any discrepancies between drawings and/or drawings and specification, should be reported to the designer prior to any work commencing. Date Revisions Ini. Drawing Title Scale Drawn By Drg.no. Rev. Date Checked By Job Title Client 1:100@A1 AMBER TAVERNS DUMBARTON THE CLIPPER 3 High St G82 1LF LICENSING LAYOUT AUG 26 LG 4007-60 0 1m 2m 5m Scaled @ 1:50 B A LGLG02.09.26 Additional dimensions noted. red line extended. B LG13.09.26 Layout changes to suit builders warrant. Stair dimensions noted. Seated covers removed.