Item 5 - Lomondgate Premier Inn Application - Layout Plan for Ground Floor Licensing Plan
West Dunbartonshire Council · 17 June 2025
Back to Licensing Board — 17 June 2025 and its agenda
Text extracted from the council's PDF. Layout and reading order may differ from the original.
Some pages contain no extractable text. They may be blank, graphics or scanned pages. OCR has not been applied.
Page 1
KITCHEN BAR GLASSWASH HOST STAND WS MIDMID MID MID HOT PASS BUFFET COUNTER COFFEE BUFFET COUNTER CHILL WELL MIDMID 78 COVERS MID MID AC 2m 4m 6m 8m 10m 20m0 PROPOSED GROUND FLOOR PLAN SCALE 1:150 @A1 FIRE EXIT 02 0103 04 05 06 07 08 09 10 11 6220 Comms FAP e 70 RECEPTION ENTRANCE LOBBY OFFICE STAFF UA WC TEAM ROOM 122 123 124 126 128 130 132 134 136 138 125 127 129 131 133 135 137 139 2 4 10 12 15 17 16 19 18 21 20 LIFT LINEN PLANT MAIN STAIR LIFT AC MID HEINKEN DAVID XL (MOBILE) CO2 (DIMS TBC) ADJ. SHELVING BIN THERMALPRINTER TILL SCREEN PED MOBILE PED MOBILE CEILING BEAM EE E VEND VEND TOILET LOBBY M. WC TOILET LOBBY F. WC UA WC STAFF CHANGE TO CAR PARK 890 Emer Emer Emer Emer Emer Emer Emer EMER EMER EMER EMER HRREmer Emer Emer MS MS Emer 886 878 85449 886 950 850 998 Emer MS Emer 15211 15018 1124 909 890 C/MS C/MS C/MS C/MS C/MS C/MS C/MS C/MS C/MS C/MS C/MS C/MS EmerEmer Emer Emer Emer Emer CO2 FB FIRE ALARM SYMBOLS FIRE ALARM PANEL HEAT DETECTOR (RATE OF RISE) MULTI SENSOR COMBINED MULTI-SENSOR AND SOUNDER BASE MANUAL CALL POINT CONTRACTOR SUPPLIED EMERGENCY LUMINAIRES SYMBOLS PUBLIC CORRIDORS - VENTILUX VANTAGE VAM3/F8CR RECESSED OVERDOOR LUMINAIRE 3 HOUR MAINTAINED FITTING CHROME c/w LEGEND RESTAURANT / RECEPTION - RECESSED LUMINAIRE 3 HOUR NON-MAINTAINED FITTING WHITE BACK OF HOUSE - JSB ZETA 1 1 ZE/3/ICEL SURFACE MOUNTED LUMINAIRE 3 HOUR NON-MAINTANED FITTING BACK OF HOUSE - VENTILUX EXLUX EXM3/F8 SURFACE MOUNTED LUMINAIRE 3 HOUR MAINTAINED FITTING WHITE c/w LEGEND RESTAURANT / RECEPTION - VENTILUX GLADE GDM3/F8CR CEILING MOUNTED LUMINAIRE 3 HOUR MAINTAINED FITTING CHROME c/w LEGEND SMALL POWER DISTRIBUTION & LUMINAIRES SYMBOLS EXTERNAL WALL MOUNTED FITTING (E-DENOTES COMBINED 3 HOUR NON-MAINTAINED EMERGENCY) DISABLED ALARM SYSTEM SYMBOLS DISABLED ALARM PULL SWITCH DISABLED ALARM INDICATOR STAND ALONE LOOP SOUNDER / BEACON DISABLED REFUGE INTERCOM DISABLED ALARM INDICATOR PANEL FIRE FIGHTING EQUIPMENT Emer EMER F HRR MS 6 LITRE AFFF FOAM EXTINGUISHER FLASHING BEACON FIRE FIGHTING EQUIPMENT F FB C P CO2 FIRE BLANKET WET CHEMICAL EXTINGUISHER 2KG Co2 EXTINGUISHER 6 LITRE POWDER ABC FIRE EXTINGUISHER 6 LITRE AFFF FOAM EXTINGUISHER LICENSED AREA FOR POINT OF SALE NOTES: EXISTING EMERGENCY LIGHTING TO CORRIDORS AND PUBLIC AREAS INSTALLED IN ACCORDANCE WITH BS5266. EXISTING FIRE ALARM SYSTEM TO HOTEL INSTALLED IN ACCORDANCE WITH BS5839. C/MS e JOB No DRAWN DRAWING No REV SCALE TITLE PROJECT REVISION DATE VER A R C H I T E C T S & D E S I G N E R S A L L I S O N P I K E 7 Buxton Road West, Disley, Stockport, Cheshire, SK12 2AE. Website: www.allisonpike.com Telephone: 01663 763000 Facsimile: 01663 766772 Email: studio@allisonpike.com © Allison Pike Partnership Limited. 13-05-2024DRAWNLJ CAM01PI1130 1:150 @A1 PROPOSED GROUND LICESNSING DUMBARTON PREMIER INN JEH REV A: BEDROOM EXTENSION ADDED & RED LINE 17/6/24 LJ REV B: LAYOUT UPDATED TO INCLUDE PUBLIC UA WC. OVERALL DIMENSIONS AND ESCAPE WIDTH DIMENSIONS ADDED. GROUND FLOOR TEAM ROOM FACILITY IDENTIFIED ON PLAN. 03/07/24 LJ REV C: RE DRAWN TO UPDATED LAYOUT WITH NEW TOILET BLOCK INCLUDED. 11-02-25
Page 2
No embedded text on this page.