Item 4(ii) LRB-2022-05
Perth and Kinross Council · 6 June 2022
Back to Local Review Body — 6 June 2022 and its agenda
Text extracted from the council's PDF. Layout and reading order may differ from the original.
Page 1
4(ii) LRB-2022-05 LRB-2022-05 21/01895/FLL – Alterations and extension to dwellinghouse, alterations to garage to form ancillary accommodation and associated works, 5 Duncan’s Place, Birnam, Dunkeld INDEX (a) Papers submitted by the Applicant (Pages 55-82) (b) Decision Notice (Pages 85-86) Report of Handling (Pages 87-96) Reference Documents (Pages 65-81) (c) Representations (Pages 97-116) 53
Page 2
54
Page 3
4(ii)(a) LRB-2022-05 LRB-2022-05 21/01895/FLL – Alterations and extension to dwellinghouse, alterations to garage to form ancillary accommodation and associated works, 5 Duncan’s Place, Birnam, Dunkeld PAPERS SUBMITTED BY THE APPLICANT 55
Page 4
56
Page 5
Notice of Review Page 1 of 4 NOTICE OF REVIEW UNDER SECTION 43A(8) OF THE TOWN AND COUNTRY PLANNING (SCOTLAND) ACT 1997 (AS AMENDED)IN RESPECT OF DECISIONS ON LOCAL DEVELOPMENTS THE TOWN AND COUNTRY PLANNING (SCHEMES OF DELEGATION AND LOCAL REVIEW PROCEDURE) (SCOTLAND) REGULATIONS 2013 THE TOWN AND COUNTRY PLANNING (APPEALS) (SCOTLAND) REGULATIONS 2008 IMPORTANT: Please read and follow the guidance notes provided when completing this form. Failure to supply all the relevant information could invalidate your notice of review. Use BLOCK CAPITALS if completing in manuscript Applicant(s) Name Address Postcode Contact Telephone 1 Contact Telephone 2 Fax No E-mail* Agent (if any) Name Address Postcode Contact Telephone 1 Contact Telephone 2 Fax No E-mail* Mark this box to confirm all contact should be through this representative: * Do you agree to correspondence regarding your review being sent by e-mail? Yes No Planning authority Planning authority’s application reference number Site address Description of proposed development Date of application Date of decision (if any) Note. This notice must be served on the planning authority within three months of the date of the decision notice or from the date of expiry of the period allowed for determining the application. =U > 7XPPJUWSR - ;NRL 5NRHGR#V ?PGHJ 3NURGQ 5XROJPI ?8/ (@5 BWXINS 6GVW 2UHMNWJHWV <WI ;NRL :GQJV D9 3XVNRJVV 4JRWUJ 7UNGUWSR AI ?JUWM ?8* /5F ().+/ ,.*(0( MJPPS1VWXINS%JGVW&HS&XO E E ?JUWM " ;NRUSVV 4SXRHNP *)'()/0-'7<< - ;NRL 5XRHGR#V ?PGHJ$ 3NURGQ$ 5XROJPI$ ?8/ (@5 2PWJUGWNSRV GRI J[WJRVNSR WS IZJPPNRLMSXVJ$ GPWJUGWNSRV WS LGUGLJ WS KSUQ GRHNPPGU\ GHHSQQSIGWNSR GRI GVVSHNGWJI ZSUOV 0 >SY *(*) 0 5JH *(*) 57
Page 6
Notice of Review Page 2 of 4 Nature of application 1. Application for planning permission (including householder application) 2. Application for planning permission in principle 3. Further application (including development that has not yet commenced and where a time limit has been imposed; renewal of planning permission; and/or modification, variation or removal of a planning condition) 4. Application for approval of matters specified in conditions Reasons for seeking review 1. Refusal of application by appointed officer 2. Failure by appointed officer to determine the application within the period allowed for determination of the application 3. Conditions imposed on consent by appointed officer Review procedure The Local Review Body will decide on the procedure to be used to determine your review and may at any time during the review process require that further information or representations be made to enable them to determine the review. Further information may be required by one or a combination of procedures, such as: written submissions; the holding of one or more hearing sessions and/or inspecting the land which is the subject of the review case. Please indicate what procedure (or combination of procedures) you think is most appropriate for the handling of your review. You may tick more than one box if you wish the review to be conducted by a combination of procedures. 1. Further written submissions 2. One or more hearing sessions 3. Site inspection 4 Assessment of review documents only, with no further procedure If you have marked box 1 or 2, please explain here which of the matters (as set out in your statement below) you believe ought to be subject of that procedure, and why you consider further submissions or a hearing are necessary: Site inspection In the event that the Local Review Body decides to inspect the review site, in your opinion: 1. Can the site be viewed entirely from public land? Yes No 2 Is it possible for the site to be accessed safely, and without barriers to entry? If there are reasons why you think the Local Review Body would be unable to undertake an unaccompanied site inspection, please explain here: " " " " " 58
Page 7
Notice of Review Page 3 of 4 Statement You must state, in full, why you are seeking a review on your application. Your statement must set out all matters you consider require to be taken into account in determining your review. Note: you may not have a further opportunity to add to your statement of review at a later date. It is therefore essential that you submit with your notice of review, all necessary information and evidence that you rely on and wish the Local Review Body to consider as part of your review. If the Local Review Body issues a notice requesting further information from any other person or body, you will have a period of 14 days in which to comment on any additional matter which has been raised by that person or body. State here the reasons for your notice of review and all matters you wish to raise. If necessary, this can be continued or provided in full in a separate document. You may also submit additional documentation with this form. Have you raised any matters which were not before the appointed officer at the time the determination on your application was made? Yes No If yes, you should explain in the box below, why you are raising new material, why it was not raised with the appointed officer before your application was determined and why you consider it should now be considered in your review. #-)&4) 4)) 4611-).)/5&39 '033)410/()/') % $+) &11-,'&5,0/ 8&4 ()5)3.,/)( ,/ & 7)39 4+035 1)3,0( 0* 5,.) 8,5+ /0 '0/5&'5 *30. 5+) &110,/5)( 0**,')3 50 '-&3,*9 &/9 10,/54 0* 26)39 03 5+) ,/5)/()( 64) 0* 5+) 130104)( ()7)-01.)/5" 59
Page 8
60
Page 9
Review Statement Planning Application Ref: 21/01895/FLL Alteration & Extension to Dwelling 5 King Duncan's Place, Birnam, Dunkeld, PH8 0QD This statement has been prepared in relation to the above planning application which was refused on 9th December 2021. The proposals include for extension of the existing dwelling and conversion and extension of the existing garage to create further ancillary accommodation associate with the dwelling. In addition, landscaping is proposed to increase the availability of parking and turning areas within the curtilage of the dwelling. This report supports the application and dismisses the reasons for refusal, demonstrating the application should be approved due to compliance with local an national planning policy and guidance. The application was determined in an unexpected short period and during the course of the application, no opportunity was given for further discussion. Reasons for Refusal The following XKGYUTY LUX XKL[YGR GTJ GYYKYYSKTZ ]OZNOT ZNK IGYK ULLOIKXdY JKRKMGZKJ XKVUXZ JU TUZ represent an adequate understanding of the proposals and application of the stated policy/guidance: 1. The proposal lacks an adequate physical and functional relationship to the host dwellinghouse. Approval would be contrary to Policies 1A and 1B(c) of Perth & Kinross Local Development Plan 2 (2019) which seek to ensure that the siting of all development respects the character and amenity of the place. 2. Approval would be contrary to Perth & Kinross Council's Placemaking Guide, March 2020 which seeks to discourage particularly large, dominant, unsuitable or inappropriately designed or located developments that are not in keeping with the existing built form, landscape character or established amenity levels. 3. Approval would be contrary to Perth & Kinross Council's Ancillary and Annex Accommodation 2021 supplementary guidance which seeks to discourage proposals which have no physical relationship to the principal dwellinghouse and as such would ultimately lead to the creation of a new residential unit. From the Case Officerds report of handling, the reasons for refusal focus on the development of the garage as ancillary accommodation. The extension to the dwelling house is seen as acceptable and in accordance with LDP2 and Supplementary guidance documents and is not brought into question. Therefore, the focus of the appeal is on the development of the garage as ancillary accommodation. 61
Page 10
Assessment Each of the above reasons for refusal will be addressed in turn below: There is no cnewd structure proposed on the site. The works are focused on an existing garage building which, by nature of its use as a garage, is an established, existing structure with both a physical and functional relationship to the main dwelling. Conversion of a garage to form additional space for a dwelling is a common form of development and in most cases would usually be considered Permitted Development. In its existing form, the garage sits in close proximity to the main dwelling, demonstrating a close physical relationship. It is also located in the immediate vicinity of the parking area and is the first structure visible when arriving on the site. The garage is used, for storage of domestic belongings, demonstrating a functional relationship with the house. The proposals maintain the physical and functional relationship with the main dwelling through the same building being converted and extended. The nature of use remains domestic in nature and it will be used, principally, to accommodate the applicants elderly relatives when they visit. A separate, safe, private, space will allow the guests to maintain some degree of independence and privacy, not disturbing the applicantds daily home and homeworking life, while being on hand for immediate care as required. The modest extension to the garage allows for the inclusion of a small kitchenette within the proposals to allow a basic level of independence to be achieved. This is not proposed to be a fully functional kitchen space, with this facility being provided in the main house. Conversion of the garage fulfils the applicantds requirement for additional space through use of an existing structure. This limits further development of the site and the use continues to respect the character and amenity of the area in accordance with Policies 1A and 1B(c) of Perth & Kinross Local Development Plan 2 (2019), Placemaking Guidance and other supplementary guidance. The proposals meet all the requirements of the Adopted Placemaking Guide (March 2020) in the following manner: (a) Create a sense of identity by developing a coherent structure of streets, spaces, and buildings, safely accessible from its surroundings. The existing streetscape will not be altered, and a close relationship of the garage and existing house creates a safe and coherent space joined by a landscaped garden area. (b) Consider and respect site topography and any surrounding important landmarks, views or skylines, as well as the wider landscape character of the area. The proposed conversion will not alter the skyline or built profile of the area and, due to existing strong tree and suburban garden planting screening, does not imapact the setting of the wider public domain. (c) The design and density should complement its surroundings in terms of appearance, height, scale, massing, materials, finishes and colours. 62
Page 11
Any new development (extension only in this case) will maintain existing floor levels (or be lower) and be no bigger than the host building. There is no prominent structure that will be viewed as incongruous with others in the local area. The proposed conversion and extension use materials that are common in the area. The area is also characterised by a mixture of design styles and material finishes (timber, render, metal, tile, slate etc.) which these proposals sit comfortably within as there is no significant alteration to the nature and character of the existing structures. (d) Respect an existing building line where appropriate, or establish one where none exists. Access, uses, and orientation of principal elevations should reinforce the street or open space. There are to be no changes the existing building lines as any extensions are both subservient to the host structure and within the private, rear garden ground of the dwelling. (e) All buildings, streets, and spaces (including green spaces) should create safe, accessible, inclusive places for people, which are easily navigable, particularly on foot, bicycle and public transport. There is no change in the accessibility of the dwelling and the provision of a safe space for an elderly relative to visit allows for robust social inclusion and support. (f) Buildings and spaces should be designed with future adaptability, climate change and resource efficiency in mind wherever possible. The existing buildings capitalise on this opportunity and are being adapted to suit the needs of the owner/occupier. The works will also allow for a sustainable development which not only meets high energy standards but makes improvements on the existing dwelling, reducing net energy consumption. (g) Existing buildings, structures and natural features that contribute to the local townscape should be retained and sensitively integrated into proposals. The proposals retain existing structures and they are being sensitively developed in a manner consistent with the residential nature of the area. (h) Incorporate green infrastructure into new developments to promote active travel and make connections where possible to blue and green networks. Existing connections with public transport, cycle and walking routes are maintained. (i) Provision of satisfactory arrangements for the storage and collection of refuse and recyclable materials (with consideration of communal facilities for major developments). The existing domestic refuse collection arrangements are maintained. (j) Sustainable design and construction. The proposals include an enhancement in the energy performance of both the existing dwelling and the converted garage. This will be a sustainable development which utilises existing structures, removing the need for unnecessary further built development on site. This a wholly sustainable practice which reduces the overall embodied energy of such a development. 63
Page 12
The application was submitted on 18th October 2021 and subsequently validated on 9th November 2021. The PKC guidance on Ancillary & Annex Accommodation 2021 was approved by the Council's Strategic Policy & Resources Committee on the 24th November 2021. In the first instance, it is unclear how this guidance document can be used to assess the application when it was adopted the date of registration. There was no communication to make the applicant aware of this guidance or that the application was subsequently then being assessed against it. However, the proposals do meet all the points mentioned in the guidance document. There is a clear functional relationship with the existing house. Comment has been raised by the case officer that a kitchen should not be included to demonstrate this functional connection. A functional relationship goes beyond the provision of a kitchen and its, proximity, use, and nature of being an existing structure fulfils those requirements. Also, we have noted that in the Ancillary & Annex Accommodation guidance JUI[SKTZ) ZNK cK^KSVRGXd proposal includes both a kitchen space and has a notably larger footprint than that of this application. There is a clear subordination to the principal house by nature of it being the existing garage. This is an established relationship. The overall height is not changing and there is only a modest increase in size. This does not affect the character and amenity of the area. Summary The assessment of policy against this application has been incorrectly applied and the prpopsals represent clear conformity with both Planning Policy, Placemaking and Supplementary Guidance documents. The proposals are for a modest, domestic development which is sensitive in size, character and materiality and maintains a clear domestic use of the existing buildings. While not required to be assessed against them, the proposals are in line with the Ancillary & Annex Accommodation guidance. The high quality design, material palate and minimal impact of the design seeks to improve and enhance the visual amenity of the surrounding built context and create a useable and well-designed space to meet the current and future needs of the applicant. 25 Feb 2022 64
Page 13
ESS Park Cottage Ordnance Survey (c) Crown Copyright 2021. All rights reserved. Licence number 100022432 Scale (@ A4) Date CLIENT PROJECT Project NumberREV King James VI Business Centre, Friarton Rd, Perth, PH2 8DY t: 01738 472090 e: hello@studio-east.co.uk PURPOSE OF ISSUE DRAWING NUMBER: This document and its contents are copyright of studioEAST. All rights reserved. Any redistribution or reproduction of part or all of the contents in any form is strictly prohibited except with our express written permission. DO NOT SCALE FOR CONSTRUCTION PURPOSES. ACCURACY OF THIS DRAWING IN PRINT FORM CANNOT BE GUARANTEED. IF IN DOUBT... ASK! 1 : 1250 21097 New Extension & Garage Conversion Neil Fullerton Oct 21 PL-01 Planning 5 King Duncans Place, Dunkeld, PH8 0QD 0 75m Scale 1:1250 10 25 50 65
Page 14
+0.10 -0.17 -0.29 -0.60 -1.80 New inspection chamber at junction to existing foul drainage - surface water discharge as existing Existing disconnecting manhole Extended parking area with new permeable paving +0.10 -0.17 -0.29 -0.60 Existing terrace to be extended to meet extension -existing ground levels around rest of extension to remain as existing -1.80 Scale (@ A3) Drawn by Date Project number Purpose of Issue Project Sheet This docum ent and its contents are copyright of studioEAST. All rights reserved. Any redistribution or reproduction of part or all of the contents in any form is strictly prohibited except with our express written permission. DO NOT SCALE FOR CONSTRUCTION PURPOSES. ACCURACY OF THIS DRAW ING IN PRINT FORM CANNOT BE GUARANTEED. IF IN DOUBT... ASK! Client King James VI Business Centre, Friarton Rd, Perth, PH2 8DY t: 01738 472090 e: hello@ studio-east.co.uk 1 : 500 Block Plans 21097 New Extension & Garage Conversion Oct 21 RG Planning PL-02 Neil Fullerton 5 King Duncans Place, Dunkeld, PH8 0QD 1 : 500 Existing Block Plan No. Description Date A Validation Points 09.11.21 1 : 500 Proposed Block Plan 0 20 Scale 1:500 10 30m ALL LEVELS RELATIVE TO EXISTING FFL OF HOUSE FFL OF NEW EXTENSION: -0.6m FFL OF NEW ANCILLARY ACCOMODATION: +0.17m 66
Page 15
9 m² Kitchen 29 m² Living 9 m² Study 12 m² Hall 13 m² Bedroom 2 4 m² Bathroom 1 m² Porch 5 m ² Utility 5 m² En Suite 10 m² Bedroom 1 32 m² Garage Scale Drawn by Date Project number This document and its contents are copyright of studioEAST. All rights reserved. Any redistribution or reproduction of part or all of the contents in any form is strictly prohibited except with our express written permission. DO NOT SCALE FOR CONSTRUCTION PURPOSES. ACCURACY OF THIS DRAW ING IN PRINT FORM CANNOT BE GUARANTEED. IF IN DOUBT... ASK! King James VI Business Centre, Friarton Rd, Perth, PH2 8DY t: 01738 472090 e: hello@ studio-east.co.uk Purpose of Issue Project: Client Sheet 1 : 100 21097 New Extension & Garage Conversion Neil Fullerton Oct 21 RG PL-03 Existing Drawings 5 King Duncans Place, Dunkeld, PH8 0QD Planning No. Description Date 1 : 100 Existing Floor Plan 1 : 100 West Elevation 0 5 8 m Scale 1:100 1 : 100 North Elevation 1 : 100 South Elevation 1 : 100 East Elevation 67
Page 16
10 m ² Utility 37 m² Living/Dining 10 m² Bedroom 1 19 m² Kitchen 20 m ² Master Bedroom 9 m² Bedroom 2/Study 13 m² Hall 1 m² Porch 4 m² Dressing 8 m² En Suite 6 m² En Suite 5 m² Bathroom 10 m² Bedroom 6 m ² Hall 20 m² Kitchen/Living cup 5 m² Office 6 m² Store/Plant Room Scale Drawn by Date Project number This document and its contents are copyright of studioEAST. All rights reserved. Any redistribution or reproduction of part or all of the contents in any form is strictly prohibited except with our express written permission. DO NOT SCALE FOR CONSTRUCTION PURPOSES. ACCURACY OF THIS DRAW ING IN PRINT FORM CANNOT BE GUARANTEED. IF IN DOUBT... ASK! King James VI Business Centre, Friarton Rd, Perth, PH2 8DY t: 01738 472090 e: hello@ studio-east.co.uk Purpose of Issue Project: Client Sheet 1 : 100 21097 New Extension & Garage Conversion Neil Fullerton Oct 21 RG PL-04 Proposed Plans 5 King Duncans Place, Dunkeld, PH8 0QD Planning No. Description Date 1 : 100 Proposed Floor Plan 1 : 100 Proposed Roof Plan 0 5 8 m Scale 1:100 Existing boiler and HW C m oved w/ boiler flue through wall Terrace extended to m eet extension New opening form ed w/ lintol over to s.e spec. Open ceiling form ed w/ ridge beam over to s.e spec. New wood burning stove w/ flue through roof New door form ed to garden w/ lintol over to s.e spec. New sliding doors to deck w/ lintol over to s.e spec. -level threshold to terrace Existing garage walls strapped and lined New tim ber fram ed alu-clad windows w/ lintol over to s.e spec. Tim ber fram ed alu-clad sliding doors to new terrace New window at high level w/ lintol over to s.e spec. New rooflight over w/ joists trim m ed to s.e spec. New opening form ed w/ lintol to s.e spec. New covered entrance form ed New parking for three cars form ed New Velux M K08 rooflights New slate roof cladding w/ zinc capping New black UVPC rainwater goods New Velux M K06 rooflights -joists trim m ed to s.e spec. New black UVPC rainwater goods New slate roof cladding w/ zinc capping Existing chim ney dem olished Existing fireplace rem oved as per s.e spec. New stepped gravel path around site to follow line of boundary Existing window cill lowered to form new door opening Existing cill lowered to form full height window to kitchen Half height wall to divide office and living room Existing door handed, cupboard rem oved New ram p form ed for electric bike storage Twin wall flue to wood burning stove Twin wall flue to woodburning stove Existing ceiling rem oved to form open ceiling New stairs form ed to living room W indow seating form ed w/ curtain recess over New wood burning stove w/ flue through roof Shuttered concrete hearth and log store New rooflight over Stud walls rem oved to s.e spec. New photovoltaic panels 68
Page 17
Scale Drawn by Date Project number This document and its contents are copyright of studioEAST. All rights reserved. Any redistribution or reproduction of part or all of the contents in any form is strictly prohibited except with our express written permission. DO NOT SCALE FOR CONSTRUCTION PURPOSES. ACCURACY OF THIS DRAW ING IN PRINT FORM CANNOT BE GUARANTEED. IF IN DOUBT... ASK! King James VI Business Centre, Friarton Rd, Perth, PH2 8DY t: 01738 472090 e: hello@ studio-east.co.uk Purpose of Issue Project: Client Sheet 1 : 100 21097 New Extension & Garage Conversion Neil Fullerton Oct 21 RG PL-05 Proposed Elevations 5 King Duncans Place, Dunkeld, PH8 0QD Planning No. Description Date 1 : 100 Proposed East Elevation 1 : 100 Proposed North Elevation 1 : 100 Proposed South Elevation 1 : 100 Proposed West Elevation -Garage 1 : 100 Proposed West Elevation 1 : 100 Proposed East Elevation -Garage Sm ooth white render cladding Lam inated glass barrier Sm ooth white render cladding New tim ber fram ed alu-clad window units New slate roof cladding w/ zinc capping New covered entrance form ed, solid door with glazed sidelight New Velux M K06 rooflights Natural horizontal larch cladding Natural horizontal larch cladding Flue for woodburning stove New tim ber fram ed glazed door New sm ooth white render finish New black UVPC rainwater goods Replacem ent tim ber fram ed alu-clad windows New tim ber fram ed alu-clad window units New horizontal natural larch cladding New sm ooth white render finish New tim ber fram ed alu-clad windows New slate roof cladding w/ zinc capping Flue for woodburning stove Replacem ent tim ber fram ed alu-clad windows New horizontal natural larch cladding Sm ooth white rendered base course New tim ber fram ed alu-clad glazing w/ lintol over to s.e spec Lam inated glass barrier to deck Flue for woodburning stove Natural horizontal larch cladding New tim ber fram ed alu-clad window units New lam inated glass barrier New black UVPC rainwater goods Replacem ent tim ber fram ed alu-clad windows New sm ooth white render finish Replacem ent tim ber fram ed alu-clad windows New tim ber fram ed alu-clad sliding doors w/ level threshold to terrace New vertical natural larch cladding New Velux M K08 rooflights New slate roof cladding w/ zinc capping New slate roof cladding w/ zinc capping 0 5 8 m Scale 1:100 New black UVPC rainwater goods Existing window infilled Raised deck form ed w/ steps down to existing terrace level Existing cill lowered to form full height window to kitchen New rooflight to hall New photovoltaic panels 69
Page 18
Scale (@ A3) Drawn by Date Project number Purpose of Issue Project Sheet This docum ent and its contents are copyright of studioEAST. All rights reserved. Any redistribution or reproduction of part or all of the contents in any form is strictly prohibited except with our express written permission. DO NOT SCALE FOR CONSTRUCTION PURPOSES. ACCURACY OF THIS DRAW ING IN PRINT FORM CANNOT BE GUARANTEED. IF IN DOUBT... ASK! Client King James VI Business Centre, Friarton Rd, Perth, PH2 8DY t: 01738 472090 e: hello@ studio-east.co.uk Proposed 3D View 21097 New Extension & Garage Conversion Oct 21 RG Planning PL-06 Neil Fullerton 5 King Duncans Place, Dunkeld, PH8 0QD No. Description Date 70
Page 19
71
Page 20
72
Page 21
24 25 W e recomm end that the stove be installed at least 10-15 cm from masonry in order to allow heat to circulate and to facilitate the cleaning of the inside and outside of the stove. A layer of wallpaper on a brick wall is normally regarded as non-!am mable material. The !oor If the stove is installed on a !ammable !oor, national and local regulations must be observed with regard to the size of the non-!ammable underlying surface that must cover the !oor be- neath the stove. The underlying surface must naturally be able to bear the weight of the stove and, if ap- plicable, the steel chim ney. Distance to furniture W e recomm end that the stove be installed 900 m m from furniture, but consideration should also be given to whether furniture, etc., will dry out as a result of its proximity to the stove. The distance to !amm able material in front of the stove is 900 mm. A wood-burning stove gets hot when it is !red. Caution m ust therefore be observed, par- ticularly with regard to children touching the stove. 1.5 The chim ney If local regulations perm it, the stove may be connected to a chimney already serving anoth- er !replace (such as an oil-burning stove or another wood-burning stove). Attention should be paid to any requirements concerning the location of !ue pipes if two or more !replaces are connected to the sam e chimney. The wood-burning stove must never be connected to a chimney to which a gas-burning stove is already connected. An e!cient, modern stove places great demands on the chimney, so have a chimney sweep check the condition of your chimney. The aperture of the chimney must comply with national and local regulations. In general, the aperture area should m easure at least 175 cm2 for wood-burning stoves. An overly large chimney aperture will m ean that too much energy will be required to heat the chimney su!ciently to achieve an acceptable draught. If you have a brick chimney with a large aperture, we recomm end that you install an insulating chimney liner of the proper diameter. This will increase the draught, and improve the fuel economy. There are no requirements with respect to speci!c chimney heights, but a chimney must be tall enough to provide a good draught, and to ensure that the smoke does not cause any problems. As a general rule, there will be a satisfactory draught if the chimney extends 4 metres above the stove and at least 100 cm above the spine of the roof. If the chimney is located along the side of the house, the top of the chimney should never be lower than the spine of the roof or the high- est point on the roof. Please note that there are often national and local regulations regulating the location of chimneys in houses with thatched roofs. Please see section 1.9 Draught. The chimney and the !ue pipe m ust be !tted with cleaning doors, which must be at least the sam e size as the chim ney’s aperture area. The chim ney must be accessible for external inspection, and it m ust be possible to access the cleaning doors and the chim ney if it is to be cleaned from the top (e.g. steel chimneys). 1.6 Connecting the !ue pipe Lift the upper cast iron top plate o! the stove. Note: The included round cast iron cover plate must be m ounted on the upper cast iron top plate if the stove is being installed with the !ue pipe to the rear. Mounting the !ue collar pointing upwards From the factory, the stove is prepared for installation with the included !ue collar (1) pointing upwards with included ball stop and screws. The ball stop, which prevents the chimney sweep from damaging the stove’s ba!e plates while sweeping, is the 145 mm long rod that is provided. Mounting the !ue collar to the rear If the stove is being installed with the !ue pipe to the rear, the round plate fixed with two screws on the back of the stove is dism ounted. The iron piece on the inside convection back panel is knocked out with light, !rm taps with a hamm er next to the sm all ”bridges” holding the piece. The cast iron cover is removed from the back panel and m ounted on the top plate. The !ue collar is centred and screwed onto the back of the stove with the clamps and screws provided. The ball stop is not used when install- ing the !ue collar to the rear. The location of the ba! es The ba!es (2) and (3), which are made from vermiculite, are mounted at the factory. Make sure that the ba!es are correct- ly assembled before lighting the stove (please see the sketch). 73
Page 22
26 27 1.7 Connecting to a brick chim ney Brick a !ue bushing securely into the wall, and insert the !ue pipe into it. The pipe m ust not extend into the actual chim ney opening, but only to the inside of the chim ney aperture. The joints between the stove/pipe and pipe/wall bushing m ust be sealed with glass tape. It is not norm ally necessary to seal between any pipe joints. If the !ue pipe transitions from horizontal to vertical, it is a good idea to install it with a gentle bend so as to avoid any loss of draught. The !ue pipe m ust be dim ensioned in accordance with national and local regulations. Morsø recom mends, however, that !ue pipes be made of 2 m m sheet steel as this will extend the service life. 1.8 Connecting to a steel chim ney If your installation involves taking the chimney straight up and through the ceiling, you must com- ply with National, Local Building Regulations or !ue manufacturers instructions concerning clear- ances to combustible materials such as walls, !oor joists and ceilings. The joint between the stove !ue collar and the stovepipe must also be sealed using glass !bre rope. It is important that the insulated !ue system is properly supported both at ceiling level and at roof level. THE STOVE MUST NOT BEAR THE W EIGHT OF THE CHIMNEY SYSTEM (See chimney man- ufacturer’s instructions). Excessive weight on the stove will inhibit expansion and could lead to damage of the stove top. Damage caused to the stove in this way would not be covered by the manufacturers guarantee. If a chimney !re should occur as a result of incorrect operation of the stove or prolonged use of wet fuel, close the vents com pletely and contact the !re brigade. Be aware of the following: Cleaning procedure: Discuss this with chim ney sweep or quali!ed installer prior to or during the stove installation. Chimney draft: If the chimney draft is naturally poor it is better to install the !ue from the top of the stove so as to minim ise any internal resistance of the !ue gases. Avoid having any m ore than 2 bends in the !ue system and lim it the length of the o!set between bends. Fresh air supply A wood-burning stove requires air for com bustion. As a result, !ring a wood-burn- ing stove will help create a healthy climate in your house. If the house is very tightly sealed, and particularly if there is a cooker hood or ventilation system in the house, it m ay be necessary to install an air grate in the room in which the wood-burning stove is installed. Otherwise there may not be enough draught in the chimney, which may result in the stove not being able to burn properly, and sm oke m ay come out of the stove when the !re door is opened. If it is necessary to install air grates, they m ust be positioned so that they cannot be obstructed. 1.9 Draught If smoke comes out of the stove when the !re door is opened, it will be due to the poor draught in the chimney. This type of stove requires at least 12 PA of chimney draught to achieve satis- factory combustion and to prevent smoke from escaping. Smoke may, however, escape in any event if the stove door is opened during vigorous !ring, so this should be avoided. The !ue gas tem perature at the rated output is 281°C relative to 20°C. If in doubt, you may want to get your chim ney sweep to m easure the draught in the chim ney. Draught The draught in the chimney is the result of the di!erence between the high tempera- ture in the chimney and the cooler temperature outside. Other factors that determine whether su! cient negative pressure can be produced to create a draught include the length and insulation of the chimney, and wind and weather conditions. The draught will be reduced when: - The tem perature di!erence is too low, e.g. in connection with a poorly insu- lated chim ney. If the chim ney is cold, it m ay help to light (burn up) a rolled-up newspaper in the chim ney’s cleaning door. - The outside tem perature is too high, e.g. during the sum m er. - There is no wind. - The chim ney is not tall enough, with the result that it sits in the lee of the roof surface or tall trees. These conditions are also associated with the greatest risk of sm oke com ing back down the chim ney. - Air is entering the chim ney in undesired places, e.g. through cracked joints or leaks in the cleaning door or the !ue pipe. - Unsealed, unused !replaces are connected to the chim ney. - The !ue pipe and chim ney are clogged up with soot due to inadequate cleaning. - The house is too tightly sealed (please see the section on Fresh air supply). A good draught is achieved when: - There is a big di!erence between the tem perature in the chim ney and outside, i.e. when the need for heating is greatest. - The weather is clear and there is a good wind. - The chim ney is of the proper height, i.e. Minim um 4 m etres above the stove, and clear of the spine of the roof. 74
Page 23
28 29 2.0 Firing/using the stove Your stove is constructed with air inlets in two places. Pre-heated, fast-m oving combustion air is added to the !re above the glass window, and is regulated using the handle above the door. The combustion air is let in when the handle is pushed to the right, and shut o! when the handle is pushed to the left. Another air inlet provides constant, pre-heated air supply which cannot be adjusted, and which comes into the combustion chamber just above the !re. This helps burn o! the last few gasses emitted by the wood while it is being heated. The stove’s rated heat output is 5,0 kW . Your new Morsø stove is EN-tested for !ring with wood, and is suitable for intermittent use. NB! W ood is a material that contains a great deal of gas (approx. 75%). The gases are released when the wood is lit and heated. For this reason, it is important that these gases are ig- nited quickly after stoking. If the wood just lies smouldering, especially after re-stoking, a lot of smoke is created which, in the worst case, may cause an explosive ignition of the gases, resulting in damage to the stove. In order to ignite the gases that are released from the wood, and to keep clear, lasting !ames during the combustion process, it is important to let in the required quantity of oxygen (air supply) at all times. The setting of the air supply, the method of ignition and the lighting intervals depend on the draught in the chimney, the wind and weather, the amount of heat required, the fuel, etc. This means that it may take some time before you get to know the correct functioning of the stove under any given circumstances. Although you can !re your Morsø stove with alm ost all kinds of wood, you should not !re with wet wood, or unseasoned wood. W ood ought to be stored under a roof for at least 1 year, and preferably 2 years, with free access to wind. W ood should be chopped as soon as possible after felling if it is to dry quickly. The wood can be used once the m oisture is less than 20%. During the test, all stoves are tested with wood with a moisture content of (16 ± 4)%. Never use driftwood as it usually has a high salt content, which dam ages both the stove and the chim ney. Im pregnated and painted wood and chipboard em it poisonous sm oke and fum es so they should not be used as fuel either Please note that liquid fuel m ay not be used in the stove. Pieces of wood with a diameter exceeding 10 cm should always be chopped. The pieces of wood should be short enough to be able to lie !at over the layers of embers, with air at both ends. The maximum length of fuel in the stove is 30 cm. The maximum quantity of fuel is approx. 2 kg/hour (max. 2 pieces of wood each time you re-stoke). The !rst few times you light the stove, the !re should be moderate so that the heat- resistant paint can harden before !ring m ore vigorously. During the hardening phase, the paint may develop obnoxious sm oke and sm ell the !rst tim e it is lit, which is very normal. Make sure that the room is well ventilated during this period. W hen heating up or cooling down, the m aterial is exposed to m ajor tem perature di!erences that m ay cause the stove to give o! creaking sounds. 2.1 Lighting instructions and fuelling intervals A lot of air is needed when lighting the stove. If you are starting with a cold stove, the door should be left ajar for the !rst few minutes and the combustion air supply opened to maximum. In order to build up an insulating layer of ash in the bottom of the stove, you should burn 1-1.5 kg of dry kindling when you light the stove the !rst time. Always keep approx. 1 cm ash in the bottom of the combustion chamber. 1. W e recommend using the “top-down” method to light your wood-burning stove. It is the most environmentally-friendly method of lighting. Use two !relighters and approx. 1.5 kg of dry kindling sticks to quickly create a glowing layer of wood. Place the !relighters directly under the top layer of kindling sticks. 2.Open the air supply as much as possible. This is done using the handle above the door. 3.After the paper/solid alcohol tablets have caught !re, leave the !re door ajar about 5-10 cm so that the chim ney draws well. 4.W hen you can see that the chimney is hot enough to draw (after 5-10 minutes), close the door. If all the necessary condi- tions are met, a thick layer of embers will have been formed in the combustion chamber after another 15-20 minutes. 75
Page 24
30 31 5.Re-stoking should normally be carried out while embers still remain. Distribute the embers in the bottom, ensuring that m ost of them are at the front of the stove. 6.Place 2 pieces of wood of approx. 0.7 kg each and ap- prox. 25-30 cm long over the em bers in a single layer, with a distance of approx. 1 cm. 7.Open the air supply to maximum and close the door; the fresh wood will then ignite within a couple of minutes. 8.Reduce the amount of combustion air to the desired po- sition, and optimal combustion will continue until there are glowing embers in the bed. Make sure that there is always enough air (oxygen) to main- tain clear, lasting !ames when, and after, reducing the amount of combustion air. During the nominal test, the stoking interval was 60-70 min- utes. 9.A new portion of wood can be added by repeating steps 5 & 6.Im portant! It is important that the fresh quantity of wood starts to burn quickly. To ensure the fuel lights quickly, open the combustion air to max. or leave the door ajar to allow in the amount of air needed to light the wood. If, however, the wood only smoulders, there will be a strong build-up of smoke, which at worst can cause an explosive ignition of the !ue gases with the risk of material damage and personal injury. The stove door should normally be opened gently the !rst 2-3 cm, then you should wait until the pressure has equalised before opening the door all the way. This technique will prevent sm oke from getting out, particularly when there is a poor draugt. The stove door should never be opened when the stove is being !red vigorously. Once the wood has burned out, it becomes glowing charcoall. If a good layer of embers has already formed on top of a su!cient layer of ash, the stove can keep warm for a very long time, not least due to the favourable qualities of the cast iron. W e would strongly recom m end that you do not leave your stove alit at night. It harm s the environm ent and constitutes very poor use of the wood as the gases in the wood do not ignite at the low tem perature, but settle as soot (unburned gases) in the chim ney and stove. Extrem e conditions, such as poor draught in the chim ney, large quantities of wood or wet wood, m ay in the worst-case scenario cause an explosive ignition. W hen !ring in the summer period, when there is minimal need for heat, the combustion will be poor. The stove provides too much heat so the combustion should be reduced. But always rem ember to m ake sure that there are lasting !ames until the wood be- comes charcoal. If you want a weaker !re, stoke up using less wood. If you !re the stove using wet wood, a lot of the fuel’s therm al energy will be spent forcing the water out of the wood, without releasing any heat to the stove. This incom plete com bustion results in a layer of soot being left in the stove, pipe and chim ney. Com parison between !ring with wood and oil: Type of wood (m oisture content 20%) No. of cubic m etres per 1000 litre oil Oak Beech Ash Sycam ore Birch Elm Com m on spruce Silver !r 7.0 7.0 7.2 7.5 8.0 8.9 10.4 10.9 76
Page 25
32 33 3.0 Routine stove m aintenance 3.1 External m aintenance The cast surface of the stove is painted with heat-resistant Senotherm paint. It is best main- tained by sim ply vacuum ing it with a soft brush attachment or wiping it down with a dry, dust-free cloth. If the stove is used too vigorously, the painted surface may assum e a greyish tinge over time, but the stove can easily be freshened up with Morsø spray paint, which is available from your local retailer. Morsø stoves are painted using a Morsø Original Black (previously called Morsø dark grey) or Morsø grey. The paint can be bought in a spray or a can. 3.2 Internal m aintenance Glass window If the stove is used correctly, very little or no soot will be deposited on the ceramic glass window. If soot does form on the glass as the stove is being lit, it will burn away once normal combustion begins in the stove. If the glass window becomes thoroughly covered in soot due to incorrect op- eration, the soot can be easily removed using a cleaning agent such as Morsø Glass Cleaner. The glass must be cold when you clean it. Avoid stoking the stove with pieces of wood that are so long that they press against the glass window when the door is closed. Ceram ic glass replacem ent Ceramic glass cannot be recycled because it has a higher melting point that ordinary glass. If ceramic glass is m ixed with ordinary glass, the raw material is spoiled, and the reclaiming process m ay be halted. Take care that the ovenproof glass does not end up am ong ordinary recycled waste. That will be a great bene!t to the environm ent. Note: Should be handed in to a recycling station as ceram ic glass. Internal cast-iron parts and/or wearing parts The ba!es and other components that come in direct contact with the !re and glowing fuel are all wearing parts. As a result, they will be particularly susceptible to burn-through. W hen used correctly, these parts will last for many years, but overly vigorous use will naturally ac- celerate the burn-through. Such parts are all easily replaced. If the ba!es are damaged and are not replaced in time, the top plate will be exposed to such high tem peratures that it may be damaged as well. Please note that no unauthorised alterations of the design m ay be undertaken, and that any parts that are replaced m ust be replaced with original Morsø parts. Reasons for sooty glass window: - The fuel is too wet. - The pieces of fuel are to big/uncut wood. - The com bustion tem perature is too low. Reasons for overly rapid wear of internal parts - Stove !red too vigorously. - Use of very dry wood (wood from old furniture). - Too m uch soot on top of the ba! es (please see the section on Cleaning). - Too m uch ash in the ash pan (please see the section on Ash). Gaskets The gaskets in the doors will wear out over tim e and should be replaced as required in order to prevent runaway combustion. Use the original Morsø gasket kit. Note: Norm al wearing parts are not covered by Morsø’s extended warranty. A selection of maintenance products (spare parts, glass cleaner, paint, gasket kit, etc.) is avail- able from your Morsø dealer. 3.3 Cleaning the stove A layer of ash and soot will form as a result of the draught in the chim ney and after sweep- ing, particularly on the top of the upper ba! e. This ash will have an insulating e!ect, which may speed up the burn-through of the ba! es. During normal cleaning, the ba!es can be rem oved from the stove. Once the ba! es have been taken out, you can access the !ue chamber above the ba! es and clean it. Clean the ba!es before reassembling them, and make sure that they are correctly assembled. Nowadays, the chimney sweep must remove the soot in the stove, in addition to sweeping the chimney and cleaning the !ue pipe. The num ber of annual sweepings/cleanings of the stove should be determ ined in consultation with your chimney sweep. Ash As noted above, there should be a layer of approx. 1 cm insulating ash in the bottom of the combustion cham ber in order to achieve a high combustion temperature. If the layer of ash is too thick, it can be brushed down into the ash pan. Empty the ash pan before it gets com pletely full so that the ash does not insulate around the grate, and thereby speed up the burn-through. In m ost cases, the ash will need to be taken away by the waste disposal company. Because em bers m ay be concealed in the ash pan for several days, it m ay be necessary to store the ash in a container made of non-!ammable m aterial before pouring it into a rubbish bag. Ash from a wood-burning stove will not be of any bene!t to your garden as fertiliser. If you have burned colour brochures, or painted or treated wood, etc., in the stove, the resulting ash m ust not be poured onto soil as it may contain heavy m etals. 77
Page 26
34 35 1. Raise the bottom ba! e slightly, and hold it in that posi- tion. This loosens the brick panels in the side. 2.Tilt one of the side brick panels and rem ove it. 3.Tilt one of the side brick panels and rem ove it. 4.Once the side brick panels have been rem oved, lower the bottom ba! e and lift it out. 5.Lift the upper ba! e out of its holder and tilt it out. 6.Make sure that the ba! es and brick panels are correctly assembled before lighting the stove after cleaning. 78
Page 27
36 37 4.0 HETAS am endm ents Health and safety precautions Special care must be taken when installing the stove such that the requirements of the Health and Safety at W ork Act are met. Handling Adequate facilities must be available for loading, unloading and site handling. Fire Cem ent Som e types of !re cem ent are caustic and should not be allowed to com e into contact with the skin. In case of contact wash imm ediately with plenty of water. Asbestos This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the course of installation then please seek specialist guidance and use appropriate protective equipment. Metal Parts W hen installing or servicing this stove care should be taken to avoid the possibility of per- sonal injury. Note of references to the current UK regulations In all cases the installation m ust comply with current Building Regulations, Local Authority Byelaws and other speci!cations or regulations as they a!ect the installation of the stove. It should be noted that the Building Regulations requirem ents may be met by adopting the relevant recommendations given in British Standards BS 8303, BS EN 15287-1:2007 as an alternative means to achieve an equivalent level of perform ance to that obtained following the guidance given in Approved Document J. Please note that it is a legal requirem ent under England and W ales Building Regulations that the installation of the stove is either carried out under Local Authority Building Control ap- proval or is installed by a Competent Person registered with a Governm ent approved Com - petent Persons Schem e. HETAS Ltd operate such a Scheme and a listing of their Registered Competent Persons can be found on their website at www.hetas.co.uk. This stove m ust not be installed into a chim ney that serves any other heating appliance. More detailed advice about existing chim ney usage NOTE: A chimney height of not less than 4.5 metres measured vertically from the outlet of the stove to the top of the chimney should be satisfactory. Alternatively the calculation proce- dure given in EN 13384-1 may be used as the basis for deciding whether a particular chimney design will provide su!cient draught. The outlet from the chim ney should be above the roof of the building in accordance with the provisions of Building Regulations Approved Docum ent J. If installation is into an existing chimney then it must be sound and have no cracks or other faults which might allow fumes into the house. Older properties, especially, may have chim - ney faults or the cross section may be too large i.e. m ore than 230 m m x 230 m m . Rem edial action should be taken, if required, seeking expert advice, if necessary. If it is found neces- sary to line the chim ney then a !ue liner suitable for solid fuel m ust be used in accordance with Building Regulations Approved Docum ent J. Any existing chimney m ust be clear of obstruction and have been swept clean imm ediately before installation of the stove. If the stove is !tted in place of an open !re then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the di!erence in combustion between the stove and the open !re. If there is no existing chim ney then any new system m ust be to the designation described above and in accordance with Building Regulations Approved Document J. A single wall m etal !uepipe is suitable for connecting the stove to the chimney but is not suitable for use as the complete chimney. The chimney and connecting !uepipe must have a m inimum diameter of 150 m m and its dim ension should be not less than the size of the outlet socket of the stove. Any bend in the chim ney or connecting !uepipe should not exceed 45°. 90° bends should not be used. Combustible material should not be located where the heat dissipating through the walls of !re- places or !ues could ignite it. Therefore when installing the stove in the presence of combustible materials due account must be taken of the guidance on the separation of combustible material given in Building Regulations Approved Document J and also in these stove instructions. If it is found that there is excessive draught in the chimney then a draught stabiliser should be !tted. Fitting of a draught stabiliser will a!ect the requirement for the permanent air supply into the room in which the stove is !tted in accordance with Approved Document J (see also combustion air supply). Com m issioning and handover Ensure all parts are !tted in accordance with the instructions. On completion of the installation allow a suitable period of tim e for any !re cement and mor- tar to dry out, before lighting the stove. Once the stove is under !re check all seals for sound- ness and check that the !ue is functioning correctly and that all products of combustion are vented safely to atmosphere via the chimney terminal. On com pletion of the installation and commissioning ensure that the operating instructions for the stove are left with the custom er. Ensure to advise the custom er on the correct use of the appliance and warn them to use only the recom m ended fuel for the stove. Advise the user what to do should smoke or fumes be emitted from the stove. The customer should be warned to use a !reguard to BS 8423:2002 (Replaces BS 6539) in the presence of children, aged and/or in!rm persons. W arning note on fum e em ission Properly installed, operated and maintained this appliance will not emit fumes into the dwelling. Occasional fumes from de-ashing and re-fuelling may occur. However, persistent fume emis- sion is potentially dangerous and must not be tolerated. If fume emission does persist, the fol- lowing immediate actions should be taken: A.Open doors and windows to ventilate room . B.Let the !re out or eject and safely dispose of fuel from the appliance. C.Check for !ue or chimney blockage, and clean if required. Do not attem pt to relight the !re until the cause of the fum e emission has been identi!ed and corrected. If necessary seek expert advice. 79
Page 28
38 39 Perm anent air vent The stove requires a permanent and adequate air supply in order for it to operate safely and e!ciently. In accordance with current Building Regulations the installer may have !tted a permanent air supply vent into the room in which the stove is installed to provide com bustion air. This air vent should not under any circumstances be shut o! or sealed. Chim ney cleaning The chim ney should be swept at least twice a year. It is important that the !ue connection and chimney are swept prior to lighting up after a prolonged shutdown period. If the stove is !tted in place of an open !re then the chim ney will require sweeping after a m onth of continuous operation. This is a precaution to ensure that any “softer” deposits left from the open !re usage have not been loosened by the higher !ue tem peratures gener- ated by the closed stove. Periods of Prolonged Non-Use If the stove is to be left unused for a prolonged period of time then it should be given a thor- ough clean to remove ash and unburned fuel residues. To enable a good !ow of air through the appliance to reduce condensation and subsequent damage, leave the air controls fully open. Use of !reguard W hen using the stove in situations where children, aged and/or in!rm persons are present a !reguard must be used to prevent accidental contact with the stove. The !reguard should be m anufactured in accordance with BS 8423:2002 (Replaces BS 6539). Use of operating tools Always use the operating tools provided when handling parts likely to be hot when the stove is in use. Aerosol sprays Do not use an aerosol spray on or near the stove when it is alight. Spare parts for the 6100 Description Product no. Inner grate frame 34611000 Upper ba!e 79610600 Bottom ba!e 79610500 Tertiary box 71610561 Glass window 79610100 Right side brick panel 79610200 Left side brick panel 79610300 Rear brick 79610400 Guarantee Product Registration MORSØ 10 YEAR GUARANTEE CERTIFICATE Behind every Morsø stove is m ore than 160 years of dedicated stove design and m anufacturing experi- ence. Quality control has always been at the heart of the production process and detailed m easures have been put into place at all key stages of the build. Accordingly, provided that the stove has been supplied by an authorised Morsø dealer, Morsø will o!er a 10-Year Manufacturers Guarantee against m anufacturing defect to any of the m ain exterior body parts of its stoves. Read m ore about ”Morsø 10 years guarantee/product registration card” and REGISTER your new Morsø stove online: http://international.m orsoe.com/warranty-registrationDK ENG 80
Page 29
MORSØ JERNSTØBERI A/S . DK-7900 NYKØBING MORS E-Mail: stoves@morsoe.com · Website: www.morsoe.com Morsø Jernstøberi A/S - 06.08.2018 - 72610400 VIGTIGT! Sådan fyrer du sikkert for miljøet og dig selv! • Brug kun tørt træ Brug kun tørt (maks. 20% fugt) og ube- handlet træ. Brændet skal være kløvet og 8 - 12 cm tykt. • Tænd op Tænd op med tørt pindebrænde (brug 1 - 2 kg). Stil lågen på klem og bliv i nær- heden af ovnen i optændingsfasen. • Godt glødelag Sørg for at have et godt glødelag inden ny påfyldning. Træet skal antænde in- denfor 2 min. Hvis træet ikke tænder, kan det i værste fald forårsage en eks- plosionsagtig antændelse af røggasser- ne med risiko for såvel materielle skader som personskader. • Indfyring Ved ny indfyring: brug 2 - 3 stk. brænde - maks. 2 - 2,5 kg. • Sørg for rigelig luft Dvs. klare og gule !ammer. • Fyr aldrig over om natten IMPORTANT! How to heat safely for the environ- ment and yourself! • Use only dry wood Use only dry (max. 20% moisture content) and untreated wood. The fuel must be split and 8 - 12 cm thick. • Light Light with dry kindling (use 1 - 2 kg). Leave the door ajar and stay close to the stove during the lighting phase. • Good layer of embers Be certain to have a good layer of em- bers before re!lling. The wood should light within 2 minutes. If the logs do not ignite it may, in an extreme case, cause the flue gases to ignite which may pose a risk to material damage or personal injury. • Refuelling When refuelling use 2 - 3 pieces of wood - no more than 2 - 2.5 kg. • Ensure adequate air I.e. clear and yellow !ames. • Never burn overnight 81
Page 30
82
Page 31
4(ii)(b) LRB-2022-05 LRB-2022-05 21/01895/FLL – Alterations and extension to dwellinghouse, alterations to garage to form ancillary accommodation and associated works, 5 Duncan’s Place, Birnam, Dunkeld PLANNING DECISION NOTICE REPORT OF HANDLING REFERENCE DOCUMENTS (included in applicant’s submission, pages 65-81) 83
Page 32
84
Page 33
85
Page 34
86
Page 35
87
Page 36
88
Page 37
89
Page 38
90
Page 39
91
Page 40
92
Page 41
93
Page 42
94
Page 43
95
Page 44
96
Page 45
4(ii)(c) LRB-2022-05 LRB-2022-05 21/01895/FLL – Alterations and extension to dwellinghouse, alterations to garage to form ancillary accommodation and associated works, 5 Duncan’s Place, Birnam, Dunkeld REPRESENTATIONS 97
Page 46
98
Page 47
99
Page 48
100
Page 49
101
Page 50
102
Page 51
103
Page 52
104
Page 53
105
Page 54
106
Page 55
107
Page 56
108
Page 57
M e m o r To Development Management & Building Standards Service Manager Your ref 21/01895/FLL Date 30 November 2021 Communities a n d u m From Regulatory Services Manager Our ref OLW Tel No Pullar House, 35 Kinnoull Street, Perth PH1 5GD Consultation on an Application for Planning Permission PKC 21/01895/FLL RE: Alterations and extension to dwellinghouse, alterations to garage to form ancillary accommodation and associated works 5 King Duncan's Place Birnam Dunkeld PH8 0QD for Mr Neil Fullerton I refer to your letter dated 10 November 2021 in connection with the above application and have the following comments to make. Environmental Health Recommendation I have no objections to the application but recommend the undernoted informative be included on any given consent. Comments This application is for alterations and extension to a dwellinghouse and alterations to a garage to form ancillary accommodation which will include the provision of a two woodburning stoves. Air Quality Perth and Kinross Council have a duty to assess biomass boilers for capacity within the range of 50kW to 20MW in terms of nitrogen dioxide and particulate matter based on their effect on air quality in the area. This will not be necessary with the domestic sized stoves in this case and therefore I have no adverse comments to make with regards to air quality. Odour Another matter pertaining to the stoves which could cause an issue has the potential for smoke or odour disamenity. This Service has seen an increase in complaints with regards to smoke and odour due to the installation of biomass appliances. This can be caused due to poor installation and maintenance of the biomass appliances and also inadequate dispersion of emissions due to the inappropriate location and height of a flue with regards to surrounding buildings. I note from the submitted plans that the both stove flues will terminate above roof ridge height, which will aid in dispersion of emissions. I would advise that smoke/odour could be further minimised through the use of fuel recommended by the stove manufacturer. 109
Page 58
In light of the above, the residential amenity at neighbouring dwellinghouses should not be adversely affected by smoke/odour. I would therefore have no objections to this development provided that the following informative is attached to the consent. Informative The approved stove system shall be installed and thereafter operated and maintained in accordance with the manufacturer's recommendations, such that smoke odours are not exhausted into or escape into any neighbouring dwellings. Failure to do so may result in an investigation and possible action by Environmental Health under the Environmental Protection Act 1990. 110
Page 59
1 CDS Planning Local Review Body From: Steve Sent: 23 March 2022 16:22 To: CDS Planning Local Review Body Subject: Re:- Application Ref: 21/01895/FLL CAUTION: This email originated from an external organisation. Do not follow guidance, click links, or open attachments unless you have verified the sender and know the content is safe. Application Ref: 21/01895/FLL We refer to the above Planning Application– Alterations and extension to dwellinghouse, alterations to garage to form ancillary accommodation and associated works, 5 Duncan’s Place, Birnam, Dunkeld – Mr N Fullerton Further to your original refusal of the above application, we would now like to comment on that decision and the applicants subsequent appeal against that decision. We would wholeheartedly agree with your original decision dated 10/12/21. As mere local householders with no working knowledge of the planning process we would like to take this opportunity to highlight items 2 and 3 in your reasons for refusal. Item 2 states quite clearly "Approval would be contrary to the Perth & Kinross Council's Placemaking Guide, March 2020 which seeks to discourage particular large, dominant, unsuitable or inappropriately designed or located developments that are not in keeping with the exisiting build form, landscape character or established amenity levels" As we wrote in our original objection "In the Stell Park Estate of 39 dwellings, not one garage has been given permission to be converted to a separate dwelling, preventing thereby, changing the whole character of the estate". This simply backs up the council's Placemaking Guide comments. Item 3 in the original decision states:- 111
Page 60
2 "Approval would be contrary to Perth and Kinross Council's Ancillary Annex Accommodation 2021 supplementary guidance, which seeks to discourage proposals which have no physical relationship to the original dwellinghouse and as such would ultimately lead to the creation of a new residential unit". As a professional architect himself, the proposer is surely aware of these Council Guidlines with relation to the adjoining character of the location, yet he has provided an application and now an appeal, which suggests he either believes the Council's Guidlines to be wrong, or he believes his plans to be in effect "superior". The occupants of the adjoining properties to the applicant have resided there from between 15 and 33 years, when the houses were originally built. The proposer has only recently moved into his current dwellinghouse and to date has not spoken to a single neighbour about his intended alterations or plans for the property. We therefore agree with your "Justification", in that " The proposal is not in accordance with the Development Plan and there are no material reasons which justify departing from the Development Plan", and the appeal should be dismissed on the above mentioned grounds. Yours, Steve and Phyllis Ponsonby, 112
Page 61
1 CDS Planning Local Review Body From: Richard Taylor <rick@studio-east.co.uk> Sent: 04 April 2022 10:13 To: CDS Planning Local Review Body Cc: Neil Fullerton Subject: RE: LRB-2022-05 Attachments: SUPPORTING EVIDENCE.pdf Follow Up Flag: Follow up Flag Status: Flagged CAUTION: This email originated from an external organisation. Do not follow guidance, click links, or open attachments unless you have verified the sender and know the content is safe. In response to the further letter of representation received for this review, please see below response to the points raised: The objector refers to the Placemaking Guide which “seeks to discourage particular large, dominant, unsuitable or inappropriately designed or located developments that are not in keeping with the existing built form, landscape character or established amenity levels”. It has been proven, within the review documents, that the proposals are consistent with the domestic nature of the site, proportions of the existing house and design style. They are not over-dominant of the existing dwelling or ancillary buildings and do not over-develop the site or any neighbouring properties/amenity space. Please see attached photographs from the applicant demonstrating the wider built context. This shows a variety of design styles and materials. The proposals are NOT to create a separate dwelling and this is detailed not only within the scheme design but also by the nature of the application as a Householder Application. The annexe is subservient to the principal dwelling (by nature of its shared access, utilities and address) and remains incongruous in this context. The physical relationship to the existing dwelling is also clear and established for both the extension and garage conversion proposals. This is demonstrated within the appeal documents. The conversion of a garage to provide additional living accommodation is commonplace and would not normally require planning permission. In this instance the proposals request a modest addition to the garage (consistent with any larger size of domestic garage) alongside other proposals, hence the inclusion as part of a planning application. It should be reiterated that this is NOT for the creation of a new dwelling. The PKC supplementary guidance on ancillary buildings was published AFTER this application was submitted and registered and should not be used as a vehicle for determining the application. However, the proposals meet all the guidance set out within this document and have a clear functional relationship to the main dwelling. There are no requirements within this document that state there should not be a kitchen or other facility to meet this functional requirement. It should also be noted the applicant is not an architect. Furthermore, the applicant has spoken to some neighbours regarding these proposals and there have been no objections in this regard. The length of time the applicant has lived at the property is not a determining factor in the determination of the proposals. Kind Regards, Richard Taylor BSc BArch (Hons) ARB RIAS RIBA Director & Architect 113
Page 62
5 KING DUNCANS PLACE End of estate, lower than neigbouring properties and adjacent to woodland. 3 KING DUNCANS PLACE Neighbouring property with large extension visable from road. Owner has indicated his wish to upgrade to white render. ATHOLL GARDENS DUNKELD Mix of original brown pebbledash $,& 2.(/$&'& 3)*1' /',&'/ 4,*0)# MY PROPERTY 114
Page 63
STELL PARK ROAD Opposite end of estate from 5 King Duncans Place. New development of two storey properties adjacent to pebble-dash properties Stell Park. TELFORD GARDENS Leading to 5 King Duncans Place. White Render property with new roof between original pebble-dash properties. BRIDGE STREET New build property beside traditional .'%%+'"&$0) %2,($+-30 4,*0)'& *, 3)*1' render, Larch cladding and slate roof. 115
Page 64
21 INCHEWAN PLACE Local property with two storey extension with larch cladding. STELL PARK / PERTH ROAD White properties with timber balconies and slate roofs. Directly visable from 5 King Duncans place. PERTH ROAD DUNKELD New build properties with white render, Larch cladding and slate roofs. 116