Page 1
4(iii)(c) LRB-2026-07 LRB-2026-07 25/00996/IPL - Erection of a dwellinghouse (in principle), land 45 metres west of Lunanbrae, Wester Essendy, Blairgowrie, PH10 6RA Representations
Page 2
No embedded text on this page.
Page 3
SW Internal General Tuesday, 29 July 2025 Local Planner Planning and Development Perth and Kinross Council Perth PH1 5GD Dear Customer, Land 45 Metres West Of Lunanbrae, Wester Essendy, Blairgowrie, PH10 6RA Planning Ref: 25/00996/IPL Our Ref: DSCAS-0137261-59N Proposal: Erection of a dwellinghouse (in principle) Please quote our reference in all future correspondence Scottish Water has no objection to this planning application. The applicant should be aware that this does not confirm that the proposed development can currently be serviced. Please read the following carefully as there may be further action required. Scottish Water would advise the following: Water Capacity Assessment • This proposed development is within the Lintrathen Water Treatment Works catchment. Single house developments; unless utilising private water sources, are required to submit a Water Connection Application via our Customer Portal to allow us to fully appraise the proposals. We recommend that this is done at the earliest opportunity to allow for network appraisal to be carried out ahead of development proceeding. Waste Water Capacity Assessment • ccording to our records there is no public waste water infrastructure within the vicinity of this proposed development therefore we would advise applicant to investigate private treatment options. Development Operations The Bridge Buchanan Gate Business Park Cumbernauld Road Stepps Glasgow G33 6FB Development Operations Freephone Number - 0800 3890379 E-Mail - DevelopmentOperations@scottishwater.co.uk www.scottishwater.co.uk
Page 4
SW Internal General Please Note The applicant should be aware that we are unable to reserve capacity at our water and/or waste water treatment works. When planning permission has been granted and a formal connection application has been submitted, we will review the availability of capacity at that time and advise the applicant accordingly. Surface Water For reasons of sustainability and to protect our customers from potential future sewer flooding, Scottish Water will not accept any surface water connections into our combined sewer system. There may be limited exceptional circumstances where we would allow such a connection for brownfield sites only, however this will require significant justification from the customer taking account of various factors including legal, physical, and technical challenges. In order to avoid costs and delays where a surface water discharge to our combined sewer system is anticipated, the developer should refer to our guides which can be found at https://www.scottishwater.co.uk/Help-and-Resources/Document-Hub/Business-and- Developers/Connecting-to-Our-Network which detail our policy and processes to support the application process, evidence to support the intended drainage plan should be submitted at the technical application stage where we will assess this evidence in a robust manner and provide a decision that reflects the best option from environmental and customer perspectives. Next Steps: Single house developments; unless utilising private water or drainage sources, are required to submit a Water Connection Application and Waste Water Application via our Customer Portal to allow us to fully appraise the proposals. Please note that Single House developments are not required to submit a Pre-Development Enquiry form (PDE) however local network capacity will be assessed on receipt of application forms. Further information on our application and connection process for Single Household development can be found on our website https://www.scottishwater.co.uk/Business- and-Developers/NEW-Connecting-to-Our-Network/Single-Household-Customers I trust the above is acceptable however if you require any further information regarding this matter, please contact me on 0800 389 0379 or via the e-mail address below or at planningconsultations@scottishwater.co.uk. Yours sincerely, Ruth Kerr Development Services Analyst PlanningConsultations@scottishwater.co.uk
Page 5
SW Internal General Scottish Water Disclaimer: “It is important to note that the information on any such plan provided on Scottish Water’s infrastructure, is for indicative purposes only and its accuracy cannot be relied upon. When the exact location and the nature of the infrastructure on the plan is a material requirement then you should undertake an appropriate site investigation to confirm its actual position in the ground and to determine if it is suitable for its intended purpose. By using the plan you agree that Scottish Water will not be liable for any loss, damage or costs caused by relying upon it or from carrying out any such site investigation." Supplementary Guidance • Scottish Water asset plans can be obtained from our appointed asset plan providers: • Site Investigation Services (UK) Ltd • Tel: 0333 123 1223 • Email: sw@sisplan.co.uk • www.sisplan.co.uk • Scottish Water’s current minimum level of service for water pressure is 1.0 bar or 10m head at the customer’s boundary internal outlet. Any property which cannot be adequately serviced from the available pressure may require private pumping arrangements to be installed, subject to compliance with Water Byelaws. If the developer wishes to enquire about Scottish Water’s procedure for checking the water pressure in the area, then they should write to the Development Operations department at the above address. • If the connection to the public sewer and/or water main requires to be laid through land out-with public ownership, the developer must provide evidence of formal approval from the affected landowner(s) by way of a deed of servitude. • Scottish Water may only vest new water or waste water infrastructure which is to be laid through land out with public ownership where a Deed of Servitude has been obtained in our favour by the developer. • The developer should also be aware that Scottish Water requires land title to the area of land where a pumping station and/or a Sustainable Drainage System (SUDS) proposed to vest in Scottish Water is constructed. • Please find information on how to submit application to Scottish Water at our Customer Portal
Page 6
Comments to the Development Quality Manager on a Planning Application Planning Application ref. 25/00996/IPL Comments provided by C Morilly Transportation Development Officer Service/Section Transportation & Development Contact Details TransportPlanning@pkc.gov.uk Description of Proposal Erection of a single dwellinghouse (in principle) Address of site Land 45 Metres West Of Lunanbrae Wester Essendy Blairgowrie PH10 6RA, 56°34'33.1"N 3°24'11.1"W Comments on the proposal Vehicle access to the site is proposed via a new junction on the C432 public road. On submission of a detailed planning application, the applicant should consider: Vehicle access shall be detailed and formed in accordance with Perth and Kinross Council’s Road Development Guide. All drainage infrastructure shall be detailed on the site plan, demonstrating that an adequate road surface water drainage system is achievable. Junction visibility should be formed in accordance with the Design Manual for Roads and Bridges. The number of car parking spaces being provided for the dwellinghouse should be in accordance with The National Roads Development Guide, based on the number of bedrooms proposed. Should a garage be proposed for parking, the size of space within the garage must be a minimum of 7.0m x 3.0m (internal dimensions). Turning facilities shall be provided within the site to enable vehicles to enter and leave in a forward-facing gear. A swept path tracking may assist with this assessment. The intention for waste collection shall be detailed, including a safe area of hardstanding for the presentation of bins, and demonstrating that the waste lorry is afforded adequate turning and manoeuvring space if required. The development shall not commence until the following specified matters have been the subject of a formal planning application for the approval of the Council as Planning Authority: All matters regarding access, vehicle parking and turning facilities, walking and cycling facilities, the road layout, design and specification (including the disposal of surface water), and waste management provision shall be in accordance with the standards required by the Council as Roads Authority (as detailed in the National Roads Development Guide) and to the satisfaction of the Planning Authority. To determine whether the proposed junction can support the development, please detail the junction visibility splay on the site plan to ensure that it is deliverable. Further detail is required. Recommended planning condition(s) Further detail is required before Transport Planning can provide a recommendation on this proposal. Recommended informative(s) for applicant Date comments returned 06 August 2025.
Page 7
Comments to the Development Management & Building Standards Service Manager on a Planning Application Planning Application ref. 25/00996/IPL Comments provided by Alasdair Finlayson Service/Section Place Strategies Contact Details Development Contributions Officer: Email: DevelopmentContributions@pkc.gov.uk Description of Proposal Erection of a dwellinghouse (in principle) Address of site Land 45 Metres West Of Lunanbrae Wester Essendy Blairgowrie PH10 6RA Comments on the proposal Primary Education With reference to the above planning application the Council Developer Contributions Supplementary Guidance requires a financial contribution towards increased primary school capacity in areas where a primary school capacity constraint has been identified. A capacity constraint is defined as where a primary school is operating at over 80% and is likely to be operating following completion of the proposed development, extant planning permissions and Local Development Plan allocations, at or above 100% of total capacity. This application site is in the catchment of Newhill Primary School. This is one of the schools identified in Appendix 1 of the Supplementary Guidance where a capacity issue has been identified and a condition to reflect this should be attached to any planning application granted. Recommended planning condition(s) Primary Education CO01 The development shall be in accordance with the requirements of Perth & Kinross Council’s Developer Contributions and Affordable Housing Supplementary Guidance 2023 in line with Policy 5: Infrastructure Contributions of the Perth & Kinross Local Development Plan 2 (2019) with particular regard to primary education infrastructure, or such subsequent Guidance and Policy which may replace these. RCO00 Reason – To ensure the development is in accordance with the terms of the Perth and Kinross Local Development Plan 2 (2019) and to comply with the Council’s policy on Developer Contributions and Affordable Housing Supplementary Guidance 2023. Recommended informative(s) for applicant N/A Date comments returned 5 December 2025